Pump Selection

To select the right pump, follow the steps below:
Select the cylinder trying not to exceed 80% of its nominal rating on both, load and stroke.
Select the pump according to the oil volume and the number of cylinders in operation
NOTE: We must add 35 cm³ of oil per meter of hose we use.
Use the chart below as a guide; it assumes the use of one cylinder only. For several cylinders you must add up the oil capacities.